What is akatherm?

Akatherm HDPE has a high temperature and chemical resistance which makes it ideal for drainage in residential housing, commercial kitchens and laundries. It is flexible and tough for installation underground and embedded in concrete. Its closed system is perfect for trade waste applications like industrial and laboratory fluids where system integrity and secure homogenous connections are critical.

Akatherm HDPE has a complete product range consisting of pipes from 40mm to 315mm. It includes a wide range of branches, bends, traps, sanitary and connection fittings.

Product Standards

Akatherm HDPE is manufactured according to EN1519 and to be installed in accordance with EN12056. Pressurization of the pipe system is not allowed. For testing purposes 0.5 bar pressure can be applied for a short time period.

Material Advantages

System Advantages

Soil and Waste

Pipes

Hebeish Group is a licensed manufacturer of Akatherm pipes in Egypt. Pipes are produced locally by October for Plastic Pipes member of Hebeish group. The HDPE PE80 pipes are manufactured according to EN1519 and meets several quality and safety standards such as:

PIPES AND FIT TINGS

Application area B and BD are marked on pipes and fittings
B: is only for installation within the building structure
BD: Can also be used within the building structure underground

Akatherm pipes and fittings are marked with:

Fittings

Fittings inscription

Fittings
+

Y branch 45°

✕

Y-branch 45º

d1/d2Code
40/4030 04 04
50/4030 05 04
50/5030 05 05
56/4030 56 04
56/5030 56 05
56/5630 56 56
63/4030 06 04
63/5030 06 05
63/5630 06 56
63/6330 06 06
75/4030 07 04
75/5030 07 05
75/5630 07 56
75/6330 07 06
75/7530 07 07
90/4030 09 04
90/5030 09 05
90/5630 09 56
90/6330 09 06
90/7530 09 07
90/9030 09 09
110/4030 11 04
110/5030 11 05
110/5630 11 56
110/6330 11 06
110/7530 11 07
110/9030 11 09
110/11030 11 11
125/5030 12 05
125/5630 12 56
125/6330 12 06
125/7530 12 07
125/9030 12 09
125/11030 12 11
125/12530 12 12
160/50*30 16 05
160/56*30 16 56
160/63*30 16 06
160/7530 16 07
160/9030 16 09
160/11030 16 11
160/12530 16 12
160/16030 16 16
200/50**30 20 05
200/56**30 20 56
200/63**30 20 06
200/75***30 20 07
200/90***30 20 09
200/110***30 20 11
200/125***30 20 12
200/160***30 20 16
200/200***30 20 20
250/75*30 25 07
250/90*30 25 09
250/110*30 25 11
250/125*30 25 12
250/160*30 25 16
250/200*30 25 20
250/250*30 25 25
315/75*30 31 07
315/90*30 31 09
315/110*30 31 11
315/125*30 31 12
315/160*30 31 16
315/200*30 31 20
315/250*30 31 25
315/315*30 31 31
+

Triple ball branch 88.5°-135°

✕

Triple ball branch 88,5º - 135º

d1/d2Code
110/5034 11 24
110/5634 11 25
110/6334 11 26
110/7534 11 27
110/9034 11 29
110/11034 11 02
125/5034 12 24
125/5634 12 25
125/7534 12 27
125/11034 12 02
125/12534 12 22
+

Triple ball branch 88.5°-90°

✕

Triple ball branch 88,5º - 90º

d1/d2Code
110/5024 11 14
110/5624 11 15
110/6324 11 16
110/7524 11 17
110/9024 11 19
110/11024 11 01
125/5024 12 14
125/5624 12 15
125/7524 12 17
125/11024 12 01
125/12524 12 12
+

Stack-aerator

✕

Stack-aerator

d1Code
11060 11 17
16060 16 17
+

Reducer eccentric

✕

Reducer eccentric

d1/d2Code
50/4016 05 04
56/4016 56 04
56/5016 56 05
63/4016 06 04
63/5016 06 05
63/5616 06 56
75/4016 07 04
75/5016 07 05
75/5616 07 56
75/6316 07 06
90/4016 09 04
90/5016 09 05
90/5616 09 56
90/6316 09 06
90/7516 09 07
110/4016 11 04
110/5016 11 05
110/5616 11 56
110/6316 11 06
110/7516 11 07
110/9016 11 09
125/5616 12 56
125/6316 12 06
125/7516 12 07
125/9016 12 09
125/11016 12 11
160/11016 16 11
160/12516 16 12
+

Reducer eccentric long

✕

Reducer eccentric long

d1/d2Code
200/11014 20 11
200/12514 20 12
200/16014 20 16
250/20014 25 20
315/20014 31 20
315/25014 31 25
+

Reducer Concentric

✕

Reducer Concentric

d1/d2Code
40/3215 04 03
50/3215 05 03
50/4015 05 04
56/4015 56 04
56/5015 56 05
63/4015 06 04
63/5015 06 05
63/5615 06 56
75/4015 07 04
75/5015 07 05
75/5615 07 56
75/6315 07 06
90/4015 09 04
90/5015 09 05
90/5615 09 56
90/6315 09 06
90/7515 09 07
110/4015 11 04
110/5015 11 05
110/5615 11 56
110/6315 11 06
110/7515 11 07
110/9015 11 09
125/7515 12 07
125/9015 12 09
125/11015 12 11
160/11015 16 11
160/12515 16 12
200/16015 20 16*
250/16015 25 16*
250/20015 25 20*
315/20015 31 20*
315/25015 31 25*

*butt-welded only

+

Fourfold ball branch 88.5°-90°

✕

Fourfold ball branch 88,5º - 90º

d1/d2Code
110/5044 11 14
110/5644 11 15
110/6344 11 16
110/7544 11 17
110/9044 11 19
110/11044 11 01
125/5044 12 14
125/5644 12 15
125/7544 12 17
125/11044 12 01
125/12544 12 12
+

Elbow 90° long side

✕

Elbow 90º with long side

d1Code
9012 09 93
11012 11 93

One side electrofusion only

+

Elbow 88.5°

✕

Elbow 88,5º

d1Code
4012 04 88
5012 05 88
5612 56 88
6312 06 88
7512 07 88
9012 09 88
11012 11 88
12512 12 88
16012 16 88
200*12 20 88
250**12 25 88
315**12 31 88
  • * Fabricated
  • ** Fabricated, wall thickness e according to S12,5
+

Elbow 45°

✕

Elbow 45º

d1Code
4012 04 45
5012 05 45
5612 56 45
6312 06 45
7512 07 45
9012 09 45
11012 11 45
12512 12 45
16012 16 45
20012 20 45
250*12 25 45
315*12 31 45

*wall thickness e according to S12.5

+

Elbow 45° long side

✕

Elbow 45º with long side

d1Code
7512 07 46
9012 09 46
11012 11 46

Applied for making the transition from stack to building drain acc. EN12056

+

Double branch 45°

✕

Double branch 45º

d1/d2Code
110/11036 11 11
+

Double ball branch 88.5°-180°

✕

Double ball branch 88,5º - 180º

d1/d2Code
110/5024 11 34
110/5624 11 35
110/6324 11 36
110/7524 11 37
110/9024 11 39
110/11024 11 03
125/5024 12 34
125/5624 12 35
125/7524 12 37
125/11024 12 03
125/12524 12 32
+

Double ball branch 88.5°-135°

✕

Double ball branch 88,5º - 135º

d1/d2Code
110/5024 11 24
110/5624 11 25
110/6324 11 26
110/7524 11 27
110/9024 11 29
110/11024 11 02
125/5024 12 24
125/5624 12 25
125/7524 12 27
125/11024 12 02
125/12524 12 22
+

Double ball branch 88.5°-90°

✕

Double ball branch 88,5º - 90º

d1/d2Code
110/5024 11 14
110/5624 11 15
110/6324 11 16
110/7524 11 17
110/9024 11 19
110/11024 11 01
125/5024 12 14
125/5624 12 15
125/7524 12 17
125/11024 12 01
125/12524 12 12
+

Clean out branch 90°

✕

Clean out branch 90º

d1/d2Code
40/4023 04 00
50/5023 05 00
56/5623 56 00
63/6323 06 00
75/7523 07 00
90/9023 09 00
110/11023 11 20
125/11023 12 00
160/11023 16 20
200/11023 20 00
250/11023 25 00
315/11023 31 00
+

Clean out branch 45°

✕

Clean out branch 45º

d1/d2Code
110/11033 11 00
125/11033 12 00
160/11033 16 00

Clean out branches can be applied in horizontal and vertical pipes

+

Branch 88.5° swept entry

✕

Branch 88,5º swept entry

d1/d2Code
110/11025 11 11
+

Bend 90°

✕

Bend 90º

d1Code
16011 16 91
20011 20 91
25011 25 91
31511 31 91

Butt-welded only

+

Bend 90° reduced

✕

Bend 90º reduced

d1/d2Code
50/4017 05 04
63/5017 06 05

One side electrofusion only

+

Bend 88.5° electrofusable

✕

Bend 88,5º electrofusable

d1Code
11011 11 98
+

Snap socket

✕

Snap socket

d1Code
4040 04 10
5040 05 10
6360 06 10
7540 07 10
9040 09 10
11040 11 10
12540 12 10
16040 16 10
20040 20 10
+

Snap Socket Short

✕

Snap Socket Short

d1Code
11040 11 40
+

Screw coupler short

✕

Screw coupler short

d1Code
4043 04 30
5043 05 30
5643 56 30
6343 06 30
7543 07 30
9043 09 30
11043 11 30
+

Plug-in socket

✕

Plug-in socket

d1Code
4042 04 50
5042 05 50
5642 56 50
6342 06 50
7542 07 50
9042 09 50
11042 11 50
12542 12 50
16042 16 50
+

Male thread adaptor short

✕

Male thread adaptor short

d1Code
40 x 1/2"96 04 78
40 x 3/4"96 04 79
40 x 1"96 04 80
40 x 1 1/4"96 04 81
50 x 1"96 05 80
50 x 1 1/4"96 05 81
50 x 1 1/2"96 05 82
63 x 1 1/2"96 06 82
63 x 2"96 06 83
+

Male thread adaptor long

✕

Male thread adaptor long

d1Code
40 x 1/2"97 04 78
40 x 3/4"97 04 79
40 x 1"97 04 80
40 x 1/4"97 04 81
50 x 1"97 05 80
50 x 1 1/4"97 05 81
50 x 1 1/2"97 05 82
56 x 2"97 56 83
63 x 1 1/2"97 06 82
63 x 2"97 06 83
75 x 2 1/2"97 06 84
+

Flange bushing for screw coupler

✕

Flange bushing for screw coupler

d1Code
4043 04 05
5043 05 05
5643 56 05
6343 06 05
7543 07 05
9043 09 05
11043 11 05
+

Expansion socket with anchor point

✕

Expansion socket with anchor point

d1Code
4040 04 20
5040 05 20
5640 56 20
6340 06 20*
7542 07 20
9042 09 20
11042 11 20
12542 12 20
16042 16 20
20040 20 20**
25040 25 20**
31540 31 20**
+

Electrofusion coupler Akafusion

✕

Electrofusion coupler Akafusion

d1Code
4041 04 95
5041 05 05
5641 56 95
6341 06 05
7541 07 05
9041 09 95
11041 11 95
12541 12 05
16041 16 95
20041 20 65
25041 25 65
31541 31 65
+

Universal trap with flange bushing

✕

Universal trap with flange bushing

d1Code
6306 06 09
7507 07 09
9009 09 09
11011 11 09
+

S-trap

✕

S-trap

d1/d2Code
40/4004 04 01
50/4004 05 01
50/5005 05 01
56/5005 56 01
63/5005 06 01
56/5656 56 01
63/6306 06 01
75/7507 07 01
+

Running trap

✕

Running trap

d1/d2Code
40/4004 04 03
50/5005 05 03
56/5656 56 03
63/6306 06 03
+

P-trap

✕

P-trap

d1/d2Code
40/4004 04 02
50/4004 05 02
50/5005 05 02
63/5005 06 02
56/5656 56 02
63/6306 06 02
+

Floor waste gully push-fit

✕

Floor waste gully push-fit

d1/d2/d3Code
110/3x50/7546 11 05
+

Floor waste gully electrofusable

✕

Floor waste gully electrofusable

d1/d2/d3Code
110/3x56/7546 11 56
+

Wall-Lavatory bend 90° right (horizontal)

✕

Wall-Lavatory bend 90º right (horizontal)

d1/dCode
90/9050 09 33
110/9050 10 33
110/11050 11 33
+

Wall-Lavatory bend 90°

✕

Wall-Lavatory bend 90º

d1/dCode
90/9050 09 84
110/9050 11 85
110/11050 11 82
+

Floor-Lavatory bend 90°

✕

Floor-Lavatory bend 90º

d1Code
9050 09 11
11050 11 11
+

Double-wall-lavatory bend 90° (vertical)

✕

Double-wall-lavatory bend 90º (vertical)

d1/dCode
110/9050 09 34
110/11050 11 34
+

Double-wall-lavatory bend 90° (horizontal)

✕

Double-wall-lavatory bend 90º (horizontal)

d1/dCode
110/9050 09 35
110/11050 11 35

Solutions

Single stack system

Because skyscrapers are designed evermore extreme, a single stack oil & waste system offers you the possibility to aim higher. End users gain more useable space inside the building because the vent pipe is obsolete. Architects can create extreme building shapes and go ‘sky high’ because the unique aspects offer several flexible connection possibilities. Material and installation costs are reduced through low weight, the vent pipe being obsolete and prefabricated pipe segments.

Single system with Active Drainage ventilation

An alternative to secondary ventilation in high-rise Active Drainage Ventilation. An active ventilated system provides relief at the Point Of Need (P.O.N) by removing or attenuating an incoming pressure transient that, if left, could lead to trap seal depletion. The single stack solution with the P.A.P.A.s and AAVs is an ideal solution for high-rise applications, eliminating the need for roof penetrations and secondary ventilation. The combination of the P.A.P.A , Maxi-Vent and Mini-Vent AAVs support a complete system to limit pressure fluctuations, guaranteeing the integrity of the traps.

Single Stack System with Stack-Aerator

An alternative to secondary ventilation in high-rise applications in the use of a stack-aerator. A stack-aerator fitting breaks the discharge fall on each floor and, consequently, the secondary vent pipe is not required as the pressure difference stays well within the limit. The unique shape of the stack-aerator increases the capacity of the stock, allowing the soil and waste flow from the higher floors to smoothly converge with the flow on the lower floor.

Active Drainage ventilation

The Active Drainage Ventilation consists of the Studor P.A.P.A (Positive Air Pressure Attenuator) and Studor Air Admittance Valves (AAVs) that provide a complete active drainage ventilation solution, particularly suited for high-rise applications

P.A.P.A (Positive Air Pressure Attenuator)

P.A.P.A (Positive Air Pressure Attenuator) has been developed through years of research and development to solve the problems of positive pressure within drainage systems of multi-story developments

Air Admittance Valves

Air Admittance valves (A.A.V's) eliminate the need for passive pipe venting and roof penetrations with excellent performance as a result of their unique and patented design.
The negative pressure activated, one-way A.A. V's vents to protect the trap seals in the drainage system by allowing the intake of air, so that the right level of pressure within the drainage system is maintained.

Features:

Benefits:

High-rise products
+

STUDOR P.A.P.A

✕

STUDOR P.A.P.A

DNCode
75/1008F-STU616-WHB
+

STUDOR Mini-Vent

✕

STUDOR Mini-Vent NPT 1,5" with global connector

DNCode
32-6349018
+

STUDOR Maxi-Vent

✕

STUDOR Maxi-Vent with connector

DNCode
75/11049112