What is akatherm?
Akatherm HDPE has a high temperature and chemical resistance which makes it ideal for drainage in residential housing, commercial kitchens and laundries. It is flexible and tough for installation underground and embedded in concrete. Its closed system is perfect for trade waste applications like industrial and laboratory fluids where system integrity and secure homogenous connections are critical.
Akatherm HDPE has a complete product range consisting of pipes from 40mm to 315mm. It includes a wide range of branches, bends, traps, sanitary and connection fittings.
Product Standards
Akatherm HDPE is manufactured according to EN1519 and to be installed in accordance with EN12056. Pressurization of the pipe system is not allowed. For testing purposes 0.5 bar pressure can be applied for a short time period.
Material Advantages
- Impact resistant and tough: unbreakable at temperature above 5°C
- Elastic and flexible: Adjusts to local ground movement for underground use
- Thermal resistant: Applications possible between -40°C and 80°C. Up to 100°C for short periods of time
- Chemical resistant: Suitable for transport of polluted waste- water
- UV & weather resistant: Unrestricted outside use through carbon black additives
- Wear resistant: Lower cost due to long lifetime
System Advantages
- Welded system: Simple and secure installation using butt-welding and electrofusion
- Homogenous welded joints: Pull tight and leak proof for a completely closed system
- Prefabrication: Fast and cost-saving installation of repetitive systems
- Light in weight: Cost saving in transportation and handling
- Low heat conductivity: No condensation insulation required during short periods of cooling
- Non-toxic: 100% recyclable and environmentally friendly
Soil and Waste
Pipes
Hebeish Group is a licensed manufacturer of Akatherm pipes in Egypt. Pipes are produced locally by October for Plastic Pipes member of Hebeish group. The HDPE PE80 pipes are manufactured according to EN1519 and meets several quality and safety standards such as:
- ISO 8770
- EN 12666
- DIN 19535-10
- DIN 19537
PIPES AND FIT TINGS
- 32 up to 160mm are SDR 26 s12, 5 BD
- 200mm up to 315mm are SDR 33 s16 B
- Exceptions will be noted per product in the latest Akatherm Specification manual
Application area B and BD are marked on pipes and fittings
B: is only for installation within the building structure
BD: Can also be used within the building structure underground
Akatherm pipes and fittings are marked with:
- Manufacturer’s mark or brand
- Material type
- Outer diameter
- Area of Application
- Conformity of dimensions
- Production information
- Wall thickness (pipe only)
Fittings
Fittings inscription
Fittings
+
Y branch 45°
Y-branch 45º
| d1/d2 | Code |
|---|---|
| 40/40 | 30 04 04 |
| 50/40 | 30 05 04 |
| 50/50 | 30 05 05 |
| 56/40 | 30 56 04 |
| 56/50 | 30 56 05 |
| 56/56 | 30 56 56 |
| 63/40 | 30 06 04 |
| 63/50 | 30 06 05 |
| 63/56 | 30 06 56 |
| 63/63 | 30 06 06 |
| 75/40 | 30 07 04 |
| 75/50 | 30 07 05 |
| 75/56 | 30 07 56 |
| 75/63 | 30 07 06 |
| 75/75 | 30 07 07 |
| 90/40 | 30 09 04 |
| 90/50 | 30 09 05 |
| 90/56 | 30 09 56 |
| 90/63 | 30 09 06 |
| 90/75 | 30 09 07 |
| 90/90 | 30 09 09 |
| 110/40 | 30 11 04 |
| 110/50 | 30 11 05 |
| 110/56 | 30 11 56 |
| 110/63 | 30 11 06 |
| 110/75 | 30 11 07 |
| 110/90 | 30 11 09 |
| 110/110 | 30 11 11 |
| 125/50 | 30 12 05 |
| 125/56 | 30 12 56 |
| 125/63 | 30 12 06 |
| 125/75 | 30 12 07 |
| 125/90 | 30 12 09 |
| 125/110 | 30 12 11 |
| 125/125 | 30 12 12 |
| 160/50 | *30 16 05 |
| 160/56 | *30 16 56 |
| 160/63 | *30 16 06 |
| 160/75 | 30 16 07 |
| 160/90 | 30 16 09 |
| 160/110 | 30 16 11 |
| 160/125 | 30 16 12 |
| 160/160 | 30 16 16 |
| 200/50 | **30 20 05 |
| 200/56 | **30 20 56 |
| 200/63 | **30 20 06 |
| 200/75 | ***30 20 07 |
| 200/90 | ***30 20 09 |
| 200/110 | ***30 20 11 |
| 200/125 | ***30 20 12 |
| 200/160 | ***30 20 16 |
| 200/200 | ***30 20 20 |
| 250/75 | *30 25 07 |
| 250/90 | *30 25 09 |
| 250/110 | *30 25 11 |
| 250/125 | *30 25 12 |
| 250/160 | *30 25 16 |
| 250/200 | *30 25 20 |
| 250/250 | *30 25 25 |
| 315/75 | *30 31 07 |
| 315/90 | *30 31 09 |
| 315/110 | *30 31 11 |
| 315/125 | *30 31 12 |
| 315/160 | *30 31 16 |
| 315/200 | *30 31 20 |
| 315/250 | *30 31 25 |
| 315/315 | *30 31 31 |
+
Triple ball branch 88.5°-135°
Triple ball branch 88,5º - 135º
| d1/d2 | Code |
|---|---|
| 110/50 | 34 11 24 |
| 110/56 | 34 11 25 |
| 110/63 | 34 11 26 |
| 110/75 | 34 11 27 |
| 110/90 | 34 11 29 |
| 110/110 | 34 11 02 |
| 125/50 | 34 12 24 |
| 125/56 | 34 12 25 |
| 125/75 | 34 12 27 |
| 125/110 | 34 12 02 |
| 125/125 | 34 12 22 |
+
Triple ball branch 88.5°-90°
Triple ball branch 88,5º - 90º
| d1/d2 | Code |
|---|---|
| 110/50 | 24 11 14 |
| 110/56 | 24 11 15 |
| 110/63 | 24 11 16 |
| 110/75 | 24 11 17 |
| 110/90 | 24 11 19 |
| 110/110 | 24 11 01 |
| 125/50 | 24 12 14 |
| 125/56 | 24 12 15 |
| 125/75 | 24 12 17 |
| 125/110 | 24 12 01 |
| 125/125 | 24 12 12 |
+
Stack-aerator
Stack-aerator
| d1 | Code |
|---|---|
| 110 | 60 11 17 |
| 160 | 60 16 17 |
+
Reducer eccentric
Reducer eccentric
| d1/d2 | Code |
|---|---|
| 50/40 | 16 05 04 |
| 56/40 | 16 56 04 |
| 56/50 | 16 56 05 |
| 63/40 | 16 06 04 |
| 63/50 | 16 06 05 |
| 63/56 | 16 06 56 |
| 75/40 | 16 07 04 |
| 75/50 | 16 07 05 |
| 75/56 | 16 07 56 |
| 75/63 | 16 07 06 |
| 90/40 | 16 09 04 |
| 90/50 | 16 09 05 |
| 90/56 | 16 09 56 |
| 90/63 | 16 09 06 |
| 90/75 | 16 09 07 |
| 110/40 | 16 11 04 |
| 110/50 | 16 11 05 |
| 110/56 | 16 11 56 |
| 110/63 | 16 11 06 |
| 110/75 | 16 11 07 |
| 110/90 | 16 11 09 |
| 125/56 | 16 12 56 |
| 125/63 | 16 12 06 |
| 125/75 | 16 12 07 |
| 125/90 | 16 12 09 |
| 125/110 | 16 12 11 |
| 160/110 | 16 16 11 |
| 160/125 | 16 16 12 |
+
Reducer eccentric long
Reducer eccentric long
| d1/d2 | Code |
|---|---|
| 200/110 | 14 20 11 |
| 200/125 | 14 20 12 |
| 200/160 | 14 20 16 |
| 250/200 | 14 25 20 |
| 315/200 | 14 31 20 |
| 315/250 | 14 31 25 |
+
Reducer Concentric
Reducer Concentric
| d1/d2 | Code |
|---|---|
| 40/32 | 15 04 03 |
| 50/32 | 15 05 03 |
| 50/40 | 15 05 04 |
| 56/40 | 15 56 04 |
| 56/50 | 15 56 05 |
| 63/40 | 15 06 04 |
| 63/50 | 15 06 05 |
| 63/56 | 15 06 56 |
| 75/40 | 15 07 04 |
| 75/50 | 15 07 05 |
| 75/56 | 15 07 56 |
| 75/63 | 15 07 06 |
| 90/40 | 15 09 04 |
| 90/50 | 15 09 05 |
| 90/56 | 15 09 56 |
| 90/63 | 15 09 06 |
| 90/75 | 15 09 07 |
| 110/40 | 15 11 04 |
| 110/50 | 15 11 05 |
| 110/56 | 15 11 56 |
| 110/63 | 15 11 06 |
| 110/75 | 15 11 07 |
| 110/90 | 15 11 09 |
| 125/75 | 15 12 07 |
| 125/90 | 15 12 09 |
| 125/110 | 15 12 11 |
| 160/110 | 15 16 11 |
| 160/125 | 15 16 12 |
| 200/160 | 15 20 16* |
| 250/160 | 15 25 16* |
| 250/200 | 15 25 20* |
| 315/200 | 15 31 20* |
| 315/250 | 15 31 25* |
*butt-welded only
+
Fourfold ball branch 88.5°-90°
Fourfold ball branch 88,5º - 90º
| d1/d2 | Code |
|---|---|
| 110/50 | 44 11 14 |
| 110/56 | 44 11 15 |
| 110/63 | 44 11 16 |
| 110/75 | 44 11 17 |
| 110/90 | 44 11 19 |
| 110/110 | 44 11 01 |
| 125/50 | 44 12 14 |
| 125/56 | 44 12 15 |
| 125/75 | 44 12 17 |
| 125/110 | 44 12 01 |
| 125/125 | 44 12 12 |
+
Elbow 90° long side
Elbow 90º with long side
| d1 | Code |
|---|---|
| 90 | 12 09 93 |
| 110 | 12 11 93 |
One side electrofusion only
+
Elbow 88.5°
Elbow 88,5º
| d1 | Code |
|---|---|
| 40 | 12 04 88 |
| 50 | 12 05 88 |
| 56 | 12 56 88 |
| 63 | 12 06 88 |
| 75 | 12 07 88 |
| 90 | 12 09 88 |
| 110 | 12 11 88 |
| 125 | 12 12 88 |
| 160 | 12 16 88 |
| 200 | *12 20 88 |
| 250 | **12 25 88 |
| 315 | **12 31 88 |
- * Fabricated
- ** Fabricated, wall thickness e according to S12,5
+
Elbow 45°
Elbow 45º
| d1 | Code |
|---|---|
| 40 | 12 04 45 |
| 50 | 12 05 45 |
| 56 | 12 56 45 |
| 63 | 12 06 45 |
| 75 | 12 07 45 |
| 90 | 12 09 45 |
| 110 | 12 11 45 |
| 125 | 12 12 45 |
| 160 | 12 16 45 |
| 200 | 12 20 45 |
| 250 | *12 25 45 |
| 315 | *12 31 45 |
*wall thickness e according to S12.5
+
Elbow 45° long side
Elbow 45º with long side
| d1 | Code |
|---|---|
| 75 | 12 07 46 |
| 90 | 12 09 46 |
| 110 | 12 11 46 |
Applied for making the transition from stack to building drain acc. EN12056
+
Double branch 45°
Double branch 45º
| d1/d2 | Code |
|---|---|
| 110/110 | 36 11 11 |
+
Double ball branch 88.5°-180°
Double ball branch 88,5º - 180º
| d1/d2 | Code |
|---|---|
| 110/50 | 24 11 34 |
| 110/56 | 24 11 35 |
| 110/63 | 24 11 36 |
| 110/75 | 24 11 37 |
| 110/90 | 24 11 39 |
| 110/110 | 24 11 03 |
| 125/50 | 24 12 34 |
| 125/56 | 24 12 35 |
| 125/75 | 24 12 37 |
| 125/110 | 24 12 03 |
| 125/125 | 24 12 32 |
+
Double ball branch 88.5°-135°
Double ball branch 88,5º - 135º
| d1/d2 | Code |
|---|---|
| 110/50 | 24 11 24 |
| 110/56 | 24 11 25 |
| 110/63 | 24 11 26 |
| 110/75 | 24 11 27 |
| 110/90 | 24 11 29 |
| 110/110 | 24 11 02 |
| 125/50 | 24 12 24 |
| 125/56 | 24 12 25 |
| 125/75 | 24 12 27 |
| 125/110 | 24 12 02 |
| 125/125 | 24 12 22 |
+
Double ball branch 88.5°-90°
Double ball branch 88,5º - 90º
| d1/d2 | Code |
|---|---|
| 110/50 | 24 11 14 |
| 110/56 | 24 11 15 |
| 110/63 | 24 11 16 |
| 110/75 | 24 11 17 |
| 110/90 | 24 11 19 |
| 110/110 | 24 11 01 |
| 125/50 | 24 12 14 |
| 125/56 | 24 12 15 |
| 125/75 | 24 12 17 |
| 125/110 | 24 12 01 |
| 125/125 | 24 12 12 |
+
Clean out branch 90°
Clean out branch 90º
| d1/d2 | Code |
|---|---|
| 40/40 | 23 04 00 |
| 50/50 | 23 05 00 |
| 56/56 | 23 56 00 |
| 63/63 | 23 06 00 |
| 75/75 | 23 07 00 |
| 90/90 | 23 09 00 |
| 110/110 | 23 11 20 |
| 125/110 | 23 12 00 |
| 160/110 | 23 16 20 |
| 200/110 | 23 20 00 |
| 250/110 | 23 25 00 |
| 315/110 | 23 31 00 |
+
Clean out branch 45°
Clean out branch 45º
| d1/d2 | Code |
|---|---|
| 110/110 | 33 11 00 |
| 125/110 | 33 12 00 |
| 160/110 | 33 16 00 |
Clean out branches can be applied in horizontal and vertical pipes
+
Branch 88.5° swept entry
Branch 88,5º swept entry
| d1/d2 | Code |
|---|---|
| 110/110 | 25 11 11 |
+
Bend 90°
Bend 90º
| d1 | Code |
|---|---|
| 160 | 11 16 91 |
| 200 | 11 20 91 |
| 250 | 11 25 91 |
| 315 | 11 31 91 |
Butt-welded only
+
Bend 90° reduced
Bend 90º reduced
| d1/d2 | Code |
|---|---|
| 50/40 | 17 05 04 |
| 63/50 | 17 06 05 |
One side electrofusion only
+
Bend 88.5° electrofusable
Bend 88,5º electrofusable
| d1 | Code |
|---|---|
| 110 | 11 11 98 |
Connection Fittings
+
Snap socket
Snap socket
| d1 | Code |
|---|---|
| 40 | 40 04 10 |
| 50 | 40 05 10 |
| 63 | 60 06 10 |
| 75 | 40 07 10 |
| 90 | 40 09 10 |
| 110 | 40 11 10 |
| 125 | 40 12 10 |
| 160 | 40 16 10 |
| 200 | 40 20 10 |
+
Snap Socket Short
Snap Socket Short
| d1 | Code |
|---|---|
| 110 | 40 11 40 |
+
Screw coupler short
Screw coupler short
| d1 | Code |
|---|---|
| 40 | 43 04 30 |
| 50 | 43 05 30 |
| 56 | 43 56 30 |
| 63 | 43 06 30 |
| 75 | 43 07 30 |
| 90 | 43 09 30 |
| 110 | 43 11 30 |
+
Plug-in socket
Plug-in socket
| d1 | Code |
|---|---|
| 40 | 42 04 50 |
| 50 | 42 05 50 |
| 56 | 42 56 50 |
| 63 | 42 06 50 |
| 75 | 42 07 50 |
| 90 | 42 09 50 |
| 110 | 42 11 50 |
| 125 | 42 12 50 |
| 160 | 42 16 50 |
+
Male thread adaptor short
Male thread adaptor short
| d1 | Code |
|---|---|
| 40 x 1/2" | 96 04 78 |
| 40 x 3/4" | 96 04 79 |
| 40 x 1" | 96 04 80 |
| 40 x 1 1/4" | 96 04 81 |
| 50 x 1" | 96 05 80 |
| 50 x 1 1/4" | 96 05 81 |
| 50 x 1 1/2" | 96 05 82 |
| 63 x 1 1/2" | 96 06 82 |
| 63 x 2" | 96 06 83 |
+
Male thread adaptor long
Male thread adaptor long
| d1 | Code |
|---|---|
| 40 x 1/2" | 97 04 78 |
| 40 x 3/4" | 97 04 79 |
| 40 x 1" | 97 04 80 |
| 40 x 1/4" | 97 04 81 |
| 50 x 1" | 97 05 80 |
| 50 x 1 1/4" | 97 05 81 |
| 50 x 1 1/2" | 97 05 82 |
| 56 x 2" | 97 56 83 |
| 63 x 1 1/2" | 97 06 82 |
| 63 x 2" | 97 06 83 |
| 75 x 2 1/2" | 97 06 84 |
+
Flange bushing for screw coupler
Flange bushing for screw coupler
| d1 | Code |
|---|---|
| 40 | 43 04 05 |
| 50 | 43 05 05 |
| 56 | 43 56 05 |
| 63 | 43 06 05 |
| 75 | 43 07 05 |
| 90 | 43 09 05 |
| 110 | 43 11 05 |
+
Expansion socket with anchor point
Expansion socket with anchor point
| d1 | Code |
|---|---|
| 40 | 40 04 20 |
| 50 | 40 05 20 |
| 56 | 40 56 20 |
| 63 | 40 06 20* |
| 75 | 42 07 20 |
| 90 | 42 09 20 |
| 110 | 42 11 20 |
| 125 | 42 12 20 |
| 160 | 42 16 20 |
| 200 | 40 20 20** |
| 250 | 40 25 20** |
| 315 | 40 31 20** |
+
Electrofusion coupler Akafusion
Electrofusion coupler Akafusion
| d1 | Code |
|---|---|
| 40 | 41 04 95 |
| 50 | 41 05 05 |
| 56 | 41 56 95 |
| 63 | 41 06 05 |
| 75 | 41 07 05 |
| 90 | 41 09 95 |
| 110 | 41 11 95 |
| 125 | 41 12 05 |
| 160 | 41 16 95 |
| 200 | 41 20 65 |
| 250 | 41 25 65 |
| 315 | 41 31 65 |
Traps
+
Universal trap with flange bushing
Universal trap with flange bushing
| d1 | Code |
|---|---|
| 63 | 06 06 09 |
| 75 | 07 07 09 |
| 90 | 09 09 09 |
| 110 | 11 11 09 |
+
S-trap
S-trap
| d1/d2 | Code |
|---|---|
| 40/40 | 04 04 01 |
| 50/40 | 04 05 01 |
| 50/50 | 05 05 01 |
| 56/50 | 05 56 01 |
| 63/50 | 05 06 01 |
| 56/56 | 56 56 01 |
| 63/63 | 06 06 01 |
| 75/75 | 07 07 01 |
+
Running trap
Running trap
| d1/d2 | Code |
|---|---|
| 40/40 | 04 04 03 |
| 50/50 | 05 05 03 |
| 56/56 | 56 56 03 |
| 63/63 | 06 06 03 |
+
P-trap
P-trap
| d1/d2 | Code |
|---|---|
| 40/40 | 04 04 02 |
| 50/40 | 04 05 02 |
| 50/50 | 05 05 02 |
| 63/50 | 05 06 02 |
| 56/56 | 56 56 02 |
| 63/63 | 06 06 02 |
+
Floor waste gully push-fit
Floor waste gully push-fit
| d1/d2/d3 | Code |
|---|---|
| 110/3x50/75 | 46 11 05 |
+
Floor waste gully electrofusable
Floor waste gully electrofusable
| d1/d2/d3 | Code |
|---|---|
| 110/3x56/75 | 46 11 56 |
Sanitary fittings
+
Wall-Lavatory bend 90° right (horizontal)
Wall-Lavatory bend 90º right (horizontal)
| d1/d | Code |
|---|---|
| 90/90 | 50 09 33 |
| 110/90 | 50 10 33 |
| 110/110 | 50 11 33 |
+
Wall-Lavatory bend 90°
Wall-Lavatory bend 90º
| d1/d | Code |
|---|---|
| 90/90 | 50 09 84 |
| 110/90 | 50 11 85 |
| 110/110 | 50 11 82 |
+
Floor-Lavatory bend 90°
Floor-Lavatory bend 90º
| d1 | Code |
|---|---|
| 90 | 50 09 11 |
| 110 | 50 11 11 |
+
Double-wall-lavatory bend 90° (vertical)
Double-wall-lavatory bend 90º (vertical)
| d1/d | Code |
|---|---|
| 110/90 | 50 09 34 |
| 110/110 | 50 11 34 |
+
Double-wall-lavatory bend 90° (horizontal)
Double-wall-lavatory bend 90º (horizontal)
| d1/d | Code |
|---|---|
| 110/90 | 50 09 35 |
| 110/110 | 50 11 35 |
Solutions
Single stack system
Because skyscrapers are designed evermore extreme, a single stack oil & waste system offers you the possibility to aim higher. End users gain more useable space inside the building because the vent pipe is obsolete. Architects can create extreme building shapes and go ‘sky high’ because the unique aspects offer several flexible connection possibilities. Material and installation costs are reduced through low weight, the vent pipe being obsolete and prefabricated pipe segments.
Single system with Active Drainage ventilation
An alternative to secondary ventilation in high-rise Active Drainage Ventilation. An active ventilated system provides relief at the Point Of Need (P.O.N) by removing or attenuating an incoming pressure transient that, if left, could lead to trap seal depletion. The single stack solution with the P.A.P.A.s and AAVs is an ideal solution for high-rise applications, eliminating the need for roof penetrations and secondary ventilation. The combination of the P.A.P.A , Maxi-Vent and Mini-Vent AAVs support a complete system to limit pressure fluctuations, guaranteeing the integrity of the traps.
- Provides effective protection against positive pressures in the drainage system
- Scientifically proven and tested for total peace of mind.
- Reduces installed service space and less slab & roof penetrations
- Exclusively designed by in-house technical experts.
Single Stack System with Stack-Aerator
An alternative to secondary ventilation in high-rise applications in the use of a stack-aerator. A stack-aerator fitting breaks the discharge fall on each floor and, consequently, the secondary vent pipe is not required as the pressure difference stays well within the limit. The unique shape of the stack-aerator increases the capacity of the stock, allowing the soil and waste flow from the higher floors to smoothly converge with the flow on the lower floor.
Active Drainage ventilation
The Active Drainage Ventilation consists of the Studor P.A.P.A (Positive Air Pressure Attenuator) and Studor Air Admittance Valves (AAVs) that provide a complete active drainage ventilation solution, particularly suited for high-rise applications
P.A.P.A (Positive Air Pressure Attenuator)
P.A.P.A (Positive Air Pressure Attenuator) has been developed through years of research and development to solve the problems of positive pressure within drainage systems of multi-story developments
- Easy to install vertically or horizontally
- Lightweight and strong construction
- Push-fit connection
- Suitable for multi-story developments
- Resistant to most chemicals
Air Admittance Valves
Air Admittance valves (A.A.V's) eliminate the need for passive pipe venting and roof penetrations with excellent performance as a result of their unique and patented design.
The negative pressure activated, one-way A.A. V's vents to protect the trap seals in the drainage system by allowing the intake of air, so that the right level of pressure within the drainage system is maintained.
Features:
- 75/110mm pipe sizes (Maxi-Vent)
- 45/50mm pipe sizes (Mini-Vent)
- Prevents the release of foul air from the drainage system
- Can divert condensation away from the sealing membrane
- Double screen protection against foreign material or insects
Benefits:
- Constant lifetime opening and closing
- Neutralize any internal condensation for constant membrane opening ability
- Dry membrane for consistent lifetime functioning, not depending on lubrication
- 500k cycle endurance testing
High-rise products
+
STUDOR P.A.P.A
STUDOR P.A.P.A
| DN | Code |
|---|---|
| 75/100 | 8F-STU616-WHB |
+
STUDOR Mini-Vent
STUDOR Mini-Vent NPT 1,5" with global connector
| DN | Code |
|---|---|
| 32-63 | 49018 |
+
STUDOR Maxi-Vent
STUDOR Maxi-Vent with connector
| DN | Code |
|---|---|
| 75/110 | 49112 |